Egress Windows

April 22, 2011 by joe 2 Comments

Estimated reading time: 4 minutes, 8 seconds

As a remodeler in Boise, I am often asked to discuss the possibility of adding Egress windows to existing basements. I realized that the term is foreign to many folks.

What is an egress window?

Egress Windows are  those that meet or exceed a rigid set of dimensions and details that allow save exit in case of emergency. In an area where most contractors will reluctantly take a stab at putting one in for you, Levco boast and brags about installing them.

The primary issue is safety, secondary benefits include increased property value by adding natural light, and adding another legal bedroom.

Challenges include weatherproofing the concrete below the window, cutting concrete without making a mess, and ensuring proper drainage to name a few. We we have devised an excellent combination of materials and procedures that do the job perfectly.

This post has borrowed content from the good folks at Fine Home Building magazine. Although a bit complicated to understand they were able to illustrate the options well.

We have been averaging a dozen Egress Window installations a year over the past several years. Subterranean Egress Windows start at $3,900 a piece with discounts on multiples at the same address.  Each egress window we’ve installed has been a little different. Every case is unique so we insist upon viewing your particular situation before promising.

What type of window should I use?

The opening offered by a double-hung window or a horizontal sliding window would be slightly less than half of the total pane area if the window were fully operable. A casement window offers almost the entire pane area: the most egress for the size of the window. Awning windows are trickier because they often don’t open as wide as casements (if they opened all the way, they’d direct rainwater into the house). Before you buy an awning window for egress purposes, make sure it will satisfy your building inspector.

In addition to the net-clear opening, there are also requirements for sill height, as shown in the drawing. For an egress window in a below-grade basement, a window well with ladders or steps is required. (under certain circumstances)

In our opinion, the cost is a third of the added value to the home and is therefore one of  the most value added remodeling project we can offer. It also is inline with our commitment to suggesting safety oriented features. Egress is not just for subterranean applications either. Building code in Boise Idaho now requires that if you are remodeling and replacing basement windows or any windows for that matter if egress size windows are an option then you must choose to use them. See some of our projects on this site.

Two small hiccups to be aware of

  1. You must get a building permit to do the work
  2. A building permits obligates you to update the smoke detectors and carbon monoxide detectors in your home and deal with lead paint issues.

Here is the 2009 IRC updates:

EMERGENCY ESCAPE AND RESCUE OPENINGS
Both the 2009 IBC and 2009 IRC require emergency escape and rescue openings in sleeping rooms below the fourth floor of a building, and in all basements except those that are used only to house mechanical equipment which are less than 200 square feet in area. The 2009 IBC also contains some exceptions to this for rooms in buildings that are fully equipped with a fire sprinkler system, or for rooms that open directly to a corridor that leads to an exit in two directions.

Typical requirements for sizes, locations, etc., are set forth in Section 1029 of the 2009 IBC and Section R310 of the 2009 IRC. It is important to note that the required opening size of 24 inches high, 20 inches wide and 5.0 or 5.7 square feet in area must be met by “normal” operation of the window. In some cases previous editions of certain ICC legacy codes permitted the removal of a second sash, such as the upper sash in a double hung window, to be counted towards achieving the required opening size. Such an interpretation, however, is no longer applicable under the 2009 IBC and 2009 IRC.

Operable skylights and roof windows are also permitted as emergency escape and rescue openings if they meet the size requirements and the bottom of their opening is within 44 inches of the floor below.

Under the 2009 IRC, the emergency escape and rescue opening must be achieved through normal operation of the window, door or skylight without the use of keys, tools or special knowledge.

Your comments are welcome. To ask questions or get more information about remodeling, click here to email me directly, or call 208-947-7261

If you or someone you know is considering remodeling or just wants to speak to a trustworthy remodeling contractor please contact me, you’ll be glad you did.

Disclaimer: Some of these images came from the WEB. If they are yours, and you object to them being used, please claim them and I will gladly remove and replace them at once.

Related Posts

  • Fuse failure almost causes fireFuse failure almost causes fire
  • Is My House Toxic?Is My House Toxic?
  • 9 Volt Battery Safety Alert
  • Thermocouple with a button?
  • Refrigerator Failure
  • Remodeling and Your Senses

Filed Under: Egress Windows, Understanding your home, Windows

Reader Interactions

Comments

  1. Deanna Jones says

    August 18, 2015 at 12:50 pm

    Thanks for the tips! There aren’t any windows in my basement, let alone any means to leave the basement except by going upstairs, so installing egress windows seems like a good way to create a rescue opening. Knowing about the hiccups involved in building an egress window seems good to know to prepare me for any issues I may come across. It seems like the biggest issue I have to face has to do with getting the right permits to install them. Now that I know that I’ll need building permits and to update the smoke and carbon monoxide detectors, I should be able to install new egress windows.

    Reply
    • Joe Levitch says

      August 19, 2015 at 6:19 am

      I find it hard to believe that your basement has no windows. Sounds like a cellar. We typically use and existing window and make it deeper to accommodate the egress qualified one. I would have a pre-construction conference with your inspector if you are planning on doing it yourself to ensure you are not compromising your framing or will be required to install a header. As far wired together smoke and CO monitoring, Our area only requires the upgrade if things are accessible, if not, battery operated radio frequency (RF) units that talk to each other will suffice. How does it work for you in IL?

      Reply

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Primary Sidebar

Categories

  • ►Aged Home Upgrades (7)
  • ►Appliances (10)
  • ►Architecture & Design (5)
  • ►Basements (3)
  • ►Bathrooms (1)
  • ►Concrete (5)
  • ►Customer Service (3)
  • ►Deconstruction (1)
  • ►Doors (2)
  • ▼Egress Windows (1)
    • Egress Windows
  • ►Electrical (10)
  • ►Energy (7)
  • ►Engineering (2)
  • ►Environmental Awareness (2)
  • ►Excavation (1)
  • ►Finish Carpentry (2)
  • ►Fire Damage (1)
  • ►Fixing things (9)
  • ►Floors (3)
  • ►Framing (2)
  • ►Good Deals (1)
  • ►Green Remodeling (9)
  • ►Historic District Homes (3)
  • ►Home Evaluations (9)
  • ►HVAC (16)
  • ►Indoor Air Quality (9)
  • ►Insulation (5)
  • ►Insurance Work (3)
  • ►Interior Walls (2)
  • ►Lead Safe Work Practices (2)
  • ►Masonry (2)
  • ►Memoirs (3)
  • ►Moisture Protection (7)
  • ►News (2)
  • ►Plans (2)
  • ►Plumbing (34)
  • ►Problem Solving (25)
  • ►Process (4)
  • ►Roofing (5)
  • ►Safe Practices (9)
  • ►Siding (1)
  • ►Skylights & Solar Tubes (1)
  • ►Sound Proofing (1)
  • ►Terminology (1)
  • ►The Law (4)
  • ►Trust (5)
  • ►Uncategorized (1)
  • ▼Understanding your home (88)
    • 9 Volt Battery Safety Alert
    • A Visit To The Crawl Space
    • Aging in Place & Universal Design
    • Anatomy of a Door
    • Anatomy of a Roof
    • Anatomy of a Window
    • Bats in the Belfry or Flies in the Chimney
    • Building Code Updates
    • Cabinet Care and Feeding
    • Can I Just Cancel My DIY Channels?
    • Diagnosing Concrete Problems
    • Dryer not working well solution
    • Duct Cleaning
    • Egress Windows
    • Engineering 101
    • Fall checklist of To-Do's
    • Filters and Your Home
    • Fireplaces In & Out
    • Fixing Concrete Fractures
    • Foundation Moisture Protection
    • French Door Repair
    • Frost Proof Faucets
    • Galvanic Corrosion
    • Gas Oven Failure Fixed
    • Hardwood Floors
    • Help My Roof is Popping
    • Hissing sound turns out to be serious
    • Hot Water Circulation Pumps
    • How Come My Water Pressure Is Low?
    • How Hard is Your Water?
    • Hydronic Heat
    • I can't turn the HOT water off
    • I Got up on the Wrong Side of the Bed
    • I Have a Cold Room
    • I Have Knob & Tube Wiring
    • I Have Water in My Basement, Now What?
    • I Just Found Mold in my Home
    • I Like Fixing Stuff
    • Indoor Air Cooling Season
    • Is My House Toxic?
    • Joist Hangers Use & Misuse
    • Laminate Countertops
    • Levco Does Moisture Inspections
    • Little Kiss, Big Hug & Window Handing
    • Little Tricks I Have Learned
    • Living in a Leaded Home
    • Maintenance required
    • Mislabeled Electrical Panel
    • My Floor Feels Like A Trampoline
    • My House is More Humid Than Normal
    • Natural Gas
    • New Great Use For A Home Inspection
    • Ode To An Old Appliance.
    • Prepare for Vacation
    • Radon and your home
    • Refrigerator Failure
    • Remodeling and Your Senses
    • Repairing a Chimney
    • Residential Foundation Repairs
    • Roof replacement problems
    • Settling Houses
    • Shower Tile Problems
    • Skylights & Solar Tubes
    • Smoke Detectors & CO Detectors
    • Snookered by a hose
    • Sound Transmission Reduction
    • Spring Time Made it to Boise
    • Stairs 101
    • Stucco, Yesterday & Today
    • Sway Back Structure
    • Tell Me Where It Hurts
    • The Location of Things Matters
    • Thermocouple with a button?
    • Time to Replace Your Roof?
    • What are you getting for your money?
    • What Can't go Down the Toilet
    • What Does Hail Damage Do to a Roof?
    • What Does My Insurance Really Cover?
    • What Does R-Value Mean?
    • What is a Foundation Vent?
    • What is a Water Hammer
    • What is a Water Hammer
    • What is Asbestos
    • What is Molding
    • Where is My Heat Going?
    • Why Do An Energy Audit?
    • Your Copper Plumbing Pipes are Shot, NOT
    • Your Home's Thermal Envelope
  • ►Universal Design (1)
  • ►Warranty (1)
  • ►Water Awareness (12)
  • ►Weatherization (6)
  • ▼Windows (5)
    • Anatomy of a Window
    • Egress Windows
    • Little Kiss, Big Hug & Window Handing
    • Skylights & Solar Tubes
    • Why Do An Energy Audit?

Footer

CLIENT LOGIN

Levco Care

114 E 35th St Boise, ID 83714

Email: Joe@LevcoCare.com
Phone: 208.639.1808

Copyright © 2020–2023 · LevcoCare.com · Site by: CrossCadence.com · Log in

  • 208.639.1808
  • joe@levcocare.com